  https://www.phoenixcontact.com/us/products/2903116 04/26/2016???page? 1 ?/? 8 hybrid motor starter?-?elr h5-ies-sc-swd/500ac-0,6?-?2903116 please be informed that the data shown in this pdf document is generated from our online catalog. please find the complete data in the user's documentation. our general terms of use for downloads are valid (http://phoenixcontact.com/download) hybrid motor starter for reversing 3~?ac motors up to 550?v?ac, 0.6?a output current, adjustable overload shutdown and safe emergency stop up to ple/sil 3 and smartwire-dt ? adapter as a set. key commercial data packing unit 1 pc custom tariff number 85371099 country of origin germany technical data dimensions width 22.5 mm height 165 mm depth 114.5 mm ambient conditions ambient temperature (operation) -5 c ... 55 c (observe derating) ambient temperature (storage/transport) -40 c ... 80 c degree of protection ip20 device supply rated control circuit supply voltage u s 24 v dc control supply voltage range 19.2 v dc ... 30 v dc rated control supply current i s 40 ma protective circuit reverse polarity protection parallel polarity protection diode surge protection input data input name control input right/left l1l2 l3 +24v dcgnd f1f2 f3 s11 s21 s12 s22 1314 2324 a1 s33 a2 s34 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc psr-scp-24uc/esa4/2x1/1x2 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd s1 aux config. profibus-dp pow swd man. auto smartwire-dt u s l r reset logic & p reset 1/l13/l2 5/l3 2/t1 4/t2 6/t3 & error i en+ en- tm + - em-swd contactron n in 1" " swd en enen 22,5 114,5 165 aux eth2 eth1 for lan only eu5c-sed-eip-modtcp pxc rs232 24v 0v pow 24v 0v dp config. config. swd pow 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 reset prg run/prog mreset stop link psr-esa4 a1 s34 s33 s22s21 s12 a2 s11 1333 31 32 24 14 power k1k2 0511 01 +15v u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-0,6 0,6a m1 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 0,39 0,6 0,25 0,075 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m2 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m3 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m4 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m5 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 controller smartwiredt line tm emergency stop start hybrid motor starters with smartwiredt connection tm stop reset network termination plug psr safety relays ethernet connection gateway l1l2 l3 f1f2 f3 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd aux config. profibus-dp pow swd
https://www.phoenixcontact.com/us/products/2903116 04/26/2016???page? 2 ?/? 8 hybrid motor starter?-?elr h5-ies-sc-swd/500ac-0,6?-?2903116 technical data input data rated actuating voltage u c 24 v dc voltage range 19.2 v dc ... 30 v dc rated actuating current i c 5 ma switching threshold 9.6 v (0 signal) 19.2 v (1 signal) switching level < 5 v dc (for emergency stop) typical turn-off time < 30 ms output data load output output name ac output rated operating voltage u e 500 v ac operating voltage range 42 v ac ... 550 v ac mains frequency 50 hz 60 hz load current range 75 ma ... 600 ma (see to derating) trigger characteristic in acc. with iec 60947 class 10a cooling time 20 min. (for auto reset) leakage current 0 ma protective circuit surge protection output data reply output output name acknowledge output note confirmation: floating change-over contact, signal contact contact type 1 pdt switching capacity according to iec 60947-5-1 3 a (230 v, ac15) 2 a (24 v, dc13) general switching frequency 2 hz (load-dependent) mounting position vertical (horizontal din rail, motor output below) assembly instructions alignable, for spacing see derating operating mode 100% operating factor maximum power dissipation 2.5 w minimum power dissipation 0.88 w operating voltage display green led status display yellow led indication red led connection data, input side l1l2 l3 +24v dcgnd f1f2 f3 s11 s21 s12 s22 1314 2324 a1 s33 a2 s34 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc psr-scp-24uc/esa4/2x1/1x2 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd s1 aux config. profibus-dp pow swd man. auto smartwire-dt u s l r reset logic & p reset 1/l13/l2 5/l3 2/t1 4/t2 6/t3 & error i en+ en- tm + - em-swd contactron n in 1" " swd en enen 22,5 114,5 165 aux eth2 eth1 for lan only eu5c-sed-eip-modtcp pxc rs232 24v 0v pow 24v 0v dp config. config. swd pow 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 reset prg run/prog mreset stop link psr-esa4 a1 s34 s33 s22s21 s12 a2 s11 1333 31 32 24 14 power k1k2 0511 01 +15v u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-0,6 0,6a m1 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 0,39 0,6 0,25 0,075 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m2 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m3 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m4 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m5 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 controller smartwiredt line tm emergency stop start hybrid motor starters with smartwiredt connection tm stop reset network termination plug psr safety relays ethernet connection gateway l1l2 l3 f1f2 f3 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd aux config. profibus-dp pow swd
https://www.phoenixcontact.com/us/products/2903116 04/26/2016???page? 3 ?/? 8 hybrid motor starter?-?elr h5-ies-sc-swd/500ac-0,6?-?2903116 technical data connection data, input side connection name control circuits connection method screw connection stripping length 8 mm screw thread m3 conductor cross section solid 0.2 mm2 ... 2.5 mm2 conductor cross section flexible 0.2 mm2 ... 2.5 mm2 conductor cross section awg 24 ... 14 torque 0.5 nm ... 0.6 nm connection data, output side connection name load circuit connection method screw connection stripping length 8 mm screw thread m3 conductor cross section solid 0.2 mm2 ... 2.5 mm2 conductor cross section flexible 0.2 mm2 ... 2.5 mm2 conductor cross section awg 24 ... 14 torque 0.5 nm ... 0.6 nm standards/regulations designation standards/regulations standards/regulations iec?60947-1 en 60947-4-2 iec 61508 iso 13849 insulation characteristics rated insulation voltage 500 v rated surge voltage 6 kv overvoltage category iii degree of pollution 2 designation insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit insulation safe isolation (iec 60947-1) at operating voltage 300 v ac safe isolation (en 50178) at operating voltage 300 v ac basic isolation (iec 60947-1) at operating voltage 300 ... 500 v ac safe isolation (en 50178) at operating voltage 300 ... 500 v ac designation isolation characteristics between the control input and control supply voltage to auxiliary circuit insulation safe isolation (iec 60947-1) in the auxiliary circuit 300 v ac l1l2 l3 +24v dcgnd f1f2 f3 s11 s21 s12 s22 1314 2324 a1 s33 a2 s34 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc psr-scp-24uc/esa4/2x1/1x2 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd s1 aux config. profibus-dp pow swd man. auto smartwire-dt u s l r reset logic & p reset 1/l13/l2 5/l3 2/t1 4/t2 6/t3 & error i en+ en- tm + - em-swd contactron n in 1" " swd en enen 22,5 114,5 165 aux eth2 eth1 for lan only eu5c-sed-eip-modtcp pxc rs232 24v 0v pow 24v 0v dp config. config. swd pow 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 reset prg run/prog mreset stop link psr-esa4 a1 s34 s33 s22s21 s12 a2 s11 1333 31 32 24 14 power k1k2 0511 01 +15v u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-0,6 0,6a m1 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 0,39 0,6 0,25 0,075 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m2 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m3 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m4 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m5 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 controller smartwiredt line tm emergency stop start hybrid motor starters with smartwiredt connection tm stop reset network termination plug psr safety relays ethernet connection gateway l1l2 l3 f1f2 f3 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd aux config. profibus-dp pow swd
https://www.phoenixcontact.com/us/products/2903116 04/26/2016???page? 4 ?/? 8 hybrid motor starter?-?elr h5-ies-sc-swd/500ac-0,6?-?2903116 technical data insulation characteristics safe isolation (en 50178) in the auxiliary circuit 300 v ac approvals/conformities safety integrity level according to iec 61508 sil 3 (safe shutdown) sil 2 (motor protection) category acc. to en iso 13849 3 (safe shutdown) performance level according to iso 13849 e (safe shutdown) atex ? ii (2) g [ex e] [ex d] [ex px] ? ii (2) d [ex t] [ex p] eu type-examination certificate ptb 07 atex 3145 ul data sccr 100 ka (480 v ac (fuse: 30 a class cc/30 a class j (high fault))) 5 ka (480 v ac (fuse: 20 a rk5 (standard fault))) fla 0.6 a (480 v ac) group installation 20 a (class rk5, sccr 5ka, ?24 - 14 awg max. solid and stranded) 30 a (class cc or j, sccr 100ka, ?24 - 14 awg max, solid and stranded) category code nldx / nrnt standards and regulations designation standards/regulations standards/regulations iec?60947-1 en 60947-4-2 iec 61508 iso 13849 atex ? ii (2) g [ex e] [ex d] [ex px] ? ii (2) d [ex t] [ex p] classifications ecl@ss ecl@ss 4.0 27142001 ecl@ss 4.1 27142001 ecl@ss 5.0 27142001 ecl@ss 5.1 27371601 ecl@ss 6.0 27371601 ecl@ss 7.0 27371601 ecl@ss 8.0 27370905 ecl@ss 9.0 27370905 l1l2 l3 +24v dcgnd f1f2 f3 s11 s21 s12 s22 1314 2324 a1 s33 a2 s34 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc psr-scp-24uc/esa4/2x1/1x2 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd s1 aux config. profibus-dp pow swd man. auto smartwire-dt u s l r reset logic & p reset 1/l13/l2 5/l3 2/t1 4/t2 6/t3 & error i en+ en- tm + - em-swd contactron n in 1" " swd en enen 22,5 114,5 165 aux eth2 eth1 for lan only eu5c-sed-eip-modtcp pxc rs232 24v 0v pow 24v 0v dp config. config. swd pow 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 reset prg run/prog mreset stop link psr-esa4 a1 s34 s33 s22s21 s12 a2 s11 1333 31 32 24 14 power k1k2 0511 01 +15v u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-0,6 0,6a m1 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 0,39 0,6 0,25 0,075 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m2 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m3 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m4 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m5 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 controller smartwiredt line tm emergency stop start hybrid motor starters with smartwiredt connection tm stop reset network termination plug psr safety relays ethernet connection gateway l1l2 l3 f1f2 f3 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd aux config. profibus-dp pow swd
https://www.phoenixcontact.com/us/products/2903116 04/26/2016???page? 5 ?/? 8 hybrid motor starter?-?elr h5-ies-sc-swd/500ac-0,6?-?2903116 classifications etim etim 3.0 ec000035 etim 4.0 ec000066 etim 5.0 ec002055 unspsc unspsc 6.01 30211915 unspsc 7.0901 39121514 unspsc 11 39121514 unspsc 12.01 39121514 unspsc 13.2 39121514 approvals approvals approvals eac ex approvals approvals submitted approval details eac? drawings l1l2 l3 +24v dcgnd f1f2 f3 s11 s21 s12 s22 1314 2324 a1 s33 a2 s34 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc psr-scp-24uc/esa4/2x1/1x2 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd s1 aux config. profibus-dp pow swd man. auto smartwire-dt u s l r reset logic & p reset 1/l13/l2 5/l3 2/t1 4/t2 6/t3 & error i en+ en- tm + - em-swd contactron n in 1" " swd en enen 22,5 114,5 165 aux eth2 eth1 for lan only eu5c-sed-eip-modtcp pxc rs232 24v 0v pow 24v 0v dp config. config. swd pow 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 reset prg run/prog mreset stop link psr-esa4 a1 s34 s33 s22s21 s12 a2 s11 1333 31 32 24 14 power k1k2 0511 01 +15v u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-0,6 0,6a m1 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 0,39 0,6 0,25 0,075 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m2 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m3 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m4 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m5 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 controller smartwiredt line tm emergency stop start hybrid motor starters with smartwiredt connection tm stop reset network termination plug psr safety relays ethernet connection gateway l1l2 l3 f1f2 f3 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd aux config. profibus-dp pow swd
https://www.phoenixcontact.com/us/products/2903116 04/26/2016???page? 6 ?/? 8 hybrid motor starter?-?elr h5-ies-sc-swd/500ac-0,6?-?2903116 block diagram dimensional drawing application drawing l1l2 l3 +24v dcgnd f1f2 f3 s11 s21 s12 s22 1314 2324 a1 s33 a2 s34 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc psr-scp-24uc/esa4/2x1/1x2 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd s1 aux config. profibus-dp pow swd man. auto smartwire-dt u s l r reset logic & p reset 1/l13/l2 5/l3 2/t1 4/t2 6/t3 & error i en+ en- tm + - em-swd contactron n in 1" " swd en enen 22,5 114,5 165 aux eth2 eth1 for lan only eu5c-sed-eip-modtcp pxc rs232 24v 0v pow 24v 0v dp config. config. swd pow 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 reset prg run/prog mreset stop link psr-esa4 a1 s34 s33 s22s21 s12 a2 s11 1333 31 32 24 14 power k1k2 0511 01 +15v u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-0,6 0,6a m1 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 0,39 0,6 0,25 0,075 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m2 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m3 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m4 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m5 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 controller smartwiredt line tm emergency stop start hybrid motor starters with smartwiredt connection tm stop reset network termination plug psr safety relays ethernet connection gateway l1l2 l3 f1f2 f3 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd aux config. profibus-dp pow swd
https://www.phoenixcontact.com/us/products/2903116 04/26/2016???page? 7 ?/? 8 hybrid motor starter?-?elr h5-ies-sc-swd/500ac-0,6?-?2903116 circuit diagram wiring example without emergency stop l1l2 l3 +24v dcgnd f1f2 f3 s11 s21 s12 s22 1314 2324 a1 s33 a2 s34 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc psr-scp-24uc/esa4/2x1/1x2 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd s1 aux config. profibus-dp pow swd man. auto smartwire-dt u s l r reset logic & p reset 1/l13/l2 5/l3 2/t1 4/t2 6/t3 & error i en+ en- tm + - em-swd contactron n in 1" " swd en enen 22,5 114,5 165 aux eth2 eth1 for lan only eu5c-sed-eip-modtcp pxc rs232 24v 0v pow 24v 0v dp config. config. swd pow 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 reset prg run/prog mreset stop link psr-esa4 a1 s34 s33 s22s21 s12 a2 s11 1333 31 32 24 14 power k1k2 0511 01 +15v u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-0,6 0,6a m1 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 0,39 0,6 0,25 0,075 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m2 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m3 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m4 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m5 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 controller smartwiredt line tm emergency stop start hybrid motor starters with smartwiredt connection tm stop reset network termination plug psr safety relays ethernet connection gateway l1l2 l3 f1f2 f3 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd aux config. profibus-dp pow swd
https://www.phoenixcontact.com/us/products/2903116 04/26/2016???page? 8 ?/? 8 hybrid motor starter?-?elr h5-ies-sc-swd/500ac-0,6?-?2903116 circuit diagram emergency stop wiring example (two-channel) phoenix contact 2016 ? - all rights reserved http://www.phoenixcontact.com l1l2 l3 +24v dcgnd f1f2 f3 s11 s21 s12 s22 1314 2324 a1 s33 a2 s34 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc psr-scp-24uc/esa4/2x1/1x2 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd s1 aux config. profibus-dp pow swd man. auto smartwire-dt u s l r reset logic & p reset 1/l13/l2 5/l3 2/t1 4/t2 6/t3 & error i en+ en- tm + - em-swd contactron n in 1" " swd en enen 22,5 114,5 165 aux eth2 eth1 for lan only eu5c-sed-eip-modtcp pxc rs232 24v 0v pow 24v 0v dp config. config. swd pow 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 reset prg run/prog mreset stop link psr-esa4 a1 s34 s33 s22s21 s12 a2 s11 1333 31 32 24 14 power k1k2 0511 01 +15v u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-0,6 0,6a m1 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 0,39 0,6 0,25 0,075 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m2 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-2 2,4a m3 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 1,63 2,4 0,87 0,18 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m4 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 u r l e autres man 97 96 95 s max. pwr err l r reset elrh5-ies-sc-24dc/500ac-9 9a m5 en enen swd 1/l1 3/l2 5/l3 2/t1 4/t2 6/t3 6,5 9,0 4,0 1,5 controller smartwiredt line tm emergency stop start hybrid motor starters with smartwiredt connection tm stop reset network termination plug psr safety relays ethernet connection gateway l1l2 l3 f1f2 f3 m 3 ~ pe em swd-adaptercontactron n in1 eu5c swd-dp pxc 2/t1 1/l13/l2 5/l3 4/t26/t3 96 95 97 u s gnd r + C l en+ enC gnd_e man res aut swd swd en swd aux config. profibus-dp pow swd